SYKES IV LYTE-R (SODIUM CHLORIDE, SODIUM GLUCONATE, SODIUM ACETATE ANHYDROUS, POTASSIUM CHLORIDE, MAGNESIUM CHLORIDE) INJECTION, SOLUTION [SYPHARMA PTY LTD]

SYKES IV LYTE-R (SODIUM CHLORIDE, SODIUM GLUCONATE, SODIUM ACETATE ANHYDROUS, POTASSIUM CHLORIDE, MAGNESIUM CHLORIDE) INJECTION, SOLUTION [SYPHARMA PTY LTD]
PDF | XML

NDC 86043-1010-1, 86043-1010-2, 86043-1010-3, 86043-1010-4, 86043-1010-5
Set ID 2ddcac37-80b4-46c2-a0fb-cb27c338c7e7
Category PRESCRIPTION ANIMAL DRUG LABEL
Packager Sypharma Pty Ltd
Generic Name
Product Class
Product Number
Application Number
  • WARNINGS AND PRECAUTIONS

    STERILE NONPYROGENIC SOLUTION
    For Animal Use Only

  • Description

    Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) is a sterile, non-pyrogenic isotonic solution intended for fluid and electrolyte replenishment in single dose containers. May be administered intravenously or subcutaneously using aseptic technique. It contains no antimicrobial agents. Discard any unused portion. The pH is adjusted with Hydrochloric Acid and/or Sodium Hydroxide. Composition, osmolarity, pH and ionic concentration are shown in Table 1.

    Table 1

    Table1

    Osmolarity (mOsmol/L) (calc): 294 mOsmol per litre
    pH: 6.6 (limit 4.0 to 8.0)

    The container is free of PVC and phthalates. The container meets the requirements of USP and is registered with US FDA.

  • Clinical Pharmacology

    A multiple electrolyte intravenous solution is intended to restore the electrolyte balance and water for hydration. It is capable of inducing diuresis depending on the clinical condition of the patient and produces a metabolic alkalinizing effect. Acetate and gluconate ions are metabolized ultimately to carbon dioxide and water, which requires the consumption of hydrogen cations.

  • Indications and Usage

    Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) is indicated as a source of water and electrolytes for all species. It is also used as an alkalinizing agent.

  • Contraindications

    None known

  • Warnings

    The introduction of additives to any solution, regardless of type of container, requires special attention to ensure that no incompatibilities result. While some incompatibilities are readily absorbed, one must be aware that subtle physical, chemical and pharmacological incompatibilities can occur. The medical literature, the package insert and other available sources of information should be reviewed for thorough understanding of possible incompatibilities.

    Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) should be used with great care, if at all, in patients with congestive heart failure, severe renal insufficiency, and in clinical states in which there exists edema and sodium retention.

    Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) should be used with great care, if at all, in patients with hyperkalemia, severe renal failure, and in conditions in which potassium retention is present.

    Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) should be used with great care in patients with metabolic or respiratory alkalosis. The administration of acetate or gluconate ions should be done with great care in those conditions in which there is an increased level or an impaired utilization of these ions, such as severe hepatic insufficiency.

    The intravenous administration of Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) can cause fluid and/or solute overloading resulting in dilution of serum electrolyte concentrations, over-hydration, congested states, or pulmonary edema. The risk of dilutional states is inversely proportional to the electrolyte concentrations of the injection. The risk of solute overloading causing congested states with peripheral and pulmonary edema is directly proportional to the electrolyte concentrations of the injections.

    In patients with diminished renal function, administration of Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) may result in sodium or potassium retention.

  • Adverse Reactions

    Adverse reactions may occur due to the solution or the technique of administration including febrile response, infection at the site of injection or allergic reactions. Prolonged intravenous infusion of this type of product may cause venous thrombosis or phlebitis extending from the site of injection, extravasation, and hypervolemia.

    If an adverse reaction does occur, discontinue the infusion and evaluate the patient, institute appropriate therapeutic countermeasures, and save the remainder of the fluid for examination if deemed necessary.

  • Precautions

    This is a single dose unit. It contains no preservatives. Use entire contents when first opened.

    Clinical evaluation and periodic laboratory determinations are necessary to monitor changes in fluid balance, electrolyte concentrations, and acid base balance during prolonged therapy or whenever the condition of the patient warrants such evaluation.

    Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) should be used with caution. Excess administration may result in metabolic alkalosis.

    Caution must be exercised in the administration of Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) to patients receiving corticosteroids or corticotropin.

    Do not administer unless solution is clear and both seal and container are intact.

    Solution must be warmed to body temperature prior to administration and administered at a slow rate. Use solution promptly following initial entry.
    Reactions which may occur because of the solution or the technique of administration, include febrile response, infection at the site of injection, extravasation, and hypervolemia.

    If an adverse reaction does occur, discontinue the infusion and evaluate the patient, institute appropriate therapeutic countermeasures, and save the remainder of the fluid for examination if deemed necessary.

  • Dosage and Administration

    To be used as directed by a licensed veterinarian. The dosage of the Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) is dependent upon the age, weight and clinical conditions of the patient as well as laboratory determinations. Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration.

    For use in one patient on one occasion only. Discard any unused portion. Care should be taken with administration technique to avoid administration site reactions and infection.

    Additives may be incompatible. Complete information is not available. Those additives known to be incompatible should not be used. Consult with Pharmacist, if available. If, in the informed judgement of the veterinarian, it is deemed advisable to introduce additives, use aseptic technique. Mix thoroughly when additives have been introduced. Do not store solutions containing additives.

  • Over-dosage

    In an event of over-hydration or solute overload, re-evaluate the patient and institute appropriate corrective measures. See Warnings, Precautions and Adverse Events.

  • Packs Supplied

    Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) in plastic container is available as follows:

    Table2

    Exposure of pharmaceutical products to heat should be minimized. Avoid excessive heat. It is recommended the product be stored at room temperature (86°F/30°C). Protect from freezing.

  • Directions for use of plastic container

    To Open
    Tear overwrap at slit and remove solution container. Some opacity of the plastic due to moisture absorption during the sterilization process may be observed. This is normal and does not affect the solution quality or safety. The opacity will diminish gradually. Check for minute leaks by squeezing solution container firmly. If leaks are found, discard solution as sterility may be impaired. If supplemental medication is desired, follow directions below:

    Preparation for Administration
    1. Suspend container from eyelet support.
    2. Remove plastic protector from inlet/outlet port at bottom of container.
    3. Attach administration set.

    To Add Medication
    WARNING: Additives may be incompatible.

    To add medication before solution administration
    1. Prepare medication site.
    2. Using syringe with 0.63mm to 0.80mm needle, puncture medication port and inject.
    3. Mix solution and medication thoroughly. For high density medication such as potassium chloride, squeeze ports while ports are upright and mix thoroughly.

    To add medication during solution administration
    1. Close the clamp on the administration set.
    2. Prepare medication site.
    3. Using syringe with 0.63mm to 0.80mm needle, puncture medication port and inject.
    4. Remove container from IV pole and/or turn to an upright position.
    5. Evacuate both ports by squeezing them while container is in the upright position.
    6. Mix solution and medication thoroughly.
    7. Return container to in use position and continue administration.

  • GENERAL PRECAUTIONS

    CAUTION: FEDERAL LAW RESTRICTS THIS DRUG TO USE BY OR ON THE ORDER OF A LICENSED VETERINARIAN.

  • INFORMATION FOR OWNERS/CAREGIVERS

    Made in Australia

    Manufactured and distributed by:
    Sypharma Pty Ltd
    27 Healey Road Dandenong
    Victoria 3175 Australia

    For customer service email:
    customerservice@sypharma.com.au

    Version: US_01

  • Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) 250mL

    250mLIVLR

  • Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) 500mL

    500mLIVLR

  • Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) 1000mL

    1000mLIVLR

  • Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) 3000mL

    3000mLIVLR

  • Sykes IV Lyte-R Injection (Multiple Electrolytes Injection, Type 1, USP) 5000mL

    5000mLIVLR

  • INGREDIENTS AND APPEARANCE
    SYKES IV LYTE-R 
    sodium chloride, sodium gluconate, sodium acetate anhydrous, potassium chloride, magnesium chloride injection, solution
    Product Information
    Product TypePRESCRIPTION ANIMAL DRUGItem Code (Source)NDC:86043-1010
    Route of AdministrationINTRAVENOUS
    Active Ingredient/Active Moiety
    Ingredient NameBasis of StrengthStrength
    SODIUM CHLORIDE (UNII: 451W47IQ8X) (SODIUM CATION - UNII:LYR4M0NH37, CHLORIDE ION - UNII:Q32ZN48698) SODIUM CHLORIDE526 mg  in 100 mL
    SODIUM GLUCONATE (UNII: R6Q3791S76) (SODIUM CATION - UNII:LYR4M0NH37, GLUCONIC ACID - UNII:R4R8J0Q44B) SODIUM GLUCONATE502 mg  in 100 mL
    SODIUM ACETATE ANHYDROUS (UNII: NVG71ZZ7P0) (SODIUM CATION - UNII:LYR4M0NH37, ACETATE ION - UNII:569DQM74SC) SODIUM ACETATE ANHYDROUS222 mg  in 100 mL
    POTASSIUM CHLORIDE (UNII: 660YQ98I10) (POTASSIUM CATION - UNII:295O53K152) POTASSIUM CHLORIDE37 mg  in 100 mL
    MAGNESIUM CHLORIDE (UNII: 02F3473H9O) (MAGNESIUM CATION - UNII:T6V3LHY838) MAGNESIUM CHLORIDE30 mg  in 100 mL
    Inactive Ingredients
    Ingredient NameStrength
    WATER (UNII: 059QF0KO0R)  
    HYDROCHLORIC ACID (UNII: QTT17582CB)  
    SODIUM HYDROXIDE (UNII: 55X04QC32I)  
    Packaging
    #Item CodePackage DescriptionMarketing Start DateMarketing End Date
    1NDC:86043-1010-1250 mL in 1 CONTAINER
    2NDC:86043-1010-2500 mL in 1 CONTAINER
    3NDC:86043-1010-31000 mL in 1 CONTAINER
    4NDC:86043-1010-43000 mL in 1 CONTAINER
    5NDC:86043-1010-55000 mL in 1 CONTAINER
    Marketing Information
    Marketing CategoryApplication Number or Monograph CitationMarketing Start DateMarketing End Date
    unapproved drug other03/10/2016
    Labeler - Sypharma Pty Ltd (753786292)
    Registrant - Sypharma Pty Ltd (753786292)
    Establishment
    NameAddressID/FEIBusiness Operations
    Sypharma Pty Ltd753786292manufacture, pack, sterilize

Related Drugs