SODIUM CITRATE BLOOD-PACK UNITS, (PL 146 PLASTIC) (ANTICOAGULANT SODIUM CITRATE SOLUTION) SOLUTION [FENWAL, INC.]

SODIUM CITRATE BLOOD-PACK UNITS, (PL 146 PLASTIC) (ANTICOAGULANT SODIUM CITRATE SOLUTION) SOLUTION [FENWAL, INC.]
PDF | XML

NDC 0942-9502-06
Set ID 5ce5d628-0be1-431e-b8bf-b5ef97046ec4
Category Human Prescription Drug Label
Packager Fenwal, Inc.
Generic Name
Product Class Anti-coagulant
Product Number
Application Number BN770923
  • Instructions for Blood Collection and Plasmapheresis Using Double Plasmapheresis Blood-PackTM Unit

    1. Identify Blood-Pack unit using appropriate donor identification system. Confirm that the numbers on the tubing of each Blood-Pack unit container are present and identical.2. Attach one lead of a multiple lead blood-solution recipient set to a container of 0.9% Sodium Chloride Injection, USP following instructions on recipient set carton.
    3. Clamp tubing of each Blood-Pack container.
    4. Remove plug from end of manifold and immediately insert needle adapter of primed
    recipient set.
    5. Position primary container on the donor scale as far as possible below donor arm.

    6. Apply pressure to donor’s arm and disinfect site of venipuncture.

    7. If blood pressure cuff is used, inflate to approximately 60 mmHg.

    8. Remove needle cover and accomplish venipuncture per instructions below:

    a. Holding the hub and cover near the tamper-evident seal, twist cover 1/4 turn to break

    seal.

    b. Remove needle cover, being careful not to drag the cover across the needle point.

    c. Accomplish venipuncture.

    9. Open clamp on tubing of one Blood-Pack container to permit flow of blood.

    10. Mix blood and anticoagulant at several intervals during collection and immediately

    after collection.

    11. Collect specified volume of blood.

    12. Release pressure as appropriate on the donor’s arm.

    13. Make two seals below first number on container tubing, and sever tubing between seals.

    14. Flush donor tubing with intravenous solution and adjust flow to slow drip to maintain

    patency of phlebotomy needle.

    15. Centrifuge container to achieve plasma-red cell separation following standard procedures.

    16. Transfer plasma to an appropriate container. Seal transfer tubing in two places and sever

    tubing between seals.

    17. Utilize more than one identification system following standard procedures. Before infusing

    red cells, confirm the identity of the intended recipient as the original donor by

    comparing remaining segment numbers on severed tubing with segment number on

    Blood-Pack unit. Do not rely on segment numbers alone.

    18. Attach Blood-Pack unit to unused lead of recipient set. Close clamp under intravenous

    solution container and open clamp on the Blood-Pack unit. Infuse red cells.

    19. When red cells have been infused, flush tubing with intravenous solution.

    20. Close lower clamp on recipient set.

    21. If blood pressure cuff is used, inflate to approximately 60 mmHg.

    22. Repeat steps 9-19 for second unit of blood.

    23. Clamp tubing; remove needle from donor’s arm; bandage venipuncture site.

    24. Discard bags, tubing and needle according to current guidelines for handling biohazardous

  • PACKAGE/LABEL DISPLAY PANEL

    Fenwal™

    Anticoagulant Sodium Citrate Solution, USP, BLOOD-PACK™ Unit

    Double For Collection and Processing of Two 500 mL Units of Blood 16 ga. Needle

    Rx only

    Each unit consists of two PL 146 Plastic containers, each with 50 mL of Anticoagulant Sodium Citrate Solution, USP containing 2 g Sodium Citrate (dihydrate) USP.

    Not intended for storage or homologous transfusion of red cells.

    These units should be used for plasmapheresis only.

    Sterile, non-pyrogenic fluid path
    See instructions for use.

    Store at Controlled Room Temperature (refer to direction insert).

     
    Open pouch by tearing across at notch.
     
    Direct handling of product surfaces prior to extended storage in the foil pouch, may result in mold growth.
     
    Unused units in open foil pouch may be kept up to 60 days by folding and securing open end of foil pouch to prevent possible loss of moisture, provided:l) Units are not removed from foil pouch, orll) Unused units removed from foil pouch are returned to the foil pouch within 12 hours. Units may be removed from the pouch and returned only once.

    FENWAL and BLOOD-PACK are trademarks of Fenwal, Inc.

    logo Fenwal, Inc.
    Lake Zurich, IL 60047 USA
    Made in USA

    07-28-05-516 REV: A

    Y:\Drug Listings and Establishment Registration (SPL)\Drug Listings\NDA 77-923 Sodium Citrate in PL 146\4R3202MC - NDC 0942-9502-06\4R3202MC - NDC 0942-9502-06 - Version 4 - Drug Listings - December 2011\72805516 pouch.jpg
  • INGREDIENTS AND APPEARANCE
    SODIUM CITRATE BLOOD-PACK UNITS, (PL 146 PLASTIC) 
    anticoagulant sodium citrate solution solution
    Product Information
    Product TypeHUMAN PRESCRIPTION DRUGItem Code (Source)NDC:0942-9502
    Route of AdministrationINTRAVENOUS
    Active Ingredient/Active Moiety
    Ingredient NameBasis of StrengthStrength
    TRISODIUM CITRATE DIHYDRATE (UNII: B22547B95K) (Anhydrous Citric Acid - UNII:XF417D3PSL) Anhydrous Citric Acid2 g  in 50 mL
    Packaging
    #Item CodePackage DescriptionMarketing Start DateMarketing End Date
    1NDC:0942-9502-0650 mL in 1 BAG; Type 0: Not a Combination Product
    Marketing Information
    Marketing CategoryApplication Number or Monograph CitationMarketing Start DateMarketing End Date
    NDABN77092303/01/2007
    Labeler - Fenwal, Inc. (794519020)

Related Drugs