NDC | 59534-001-01, 59534-001-02, 59534-001-03, 59534-001-04, 59534-001-05, 59534-001-06, 59534-001-07, 59534-001-08, 59534-001-09, 59534-001-10, 59534-001-11, 59534-001-12, 59534-001-13 |
Set ID | 667d1826-2cd8-412e-a626-ceb8c1314313 |
Category | HUMAN PRESCRIPTION DRUG LABEL |
Packager | Richmond Oxygen Company Inc. |
Generic Name | |
Product Class | |
Product Number | |
Application Number | NDA206023 |
-
Oxygen Shoulder label
RICHMOND OXYGEN COMPNAY
11009 Richardson Road, Ashland, VA 23005
804-798-2525
OXYGEN, COMPRESSED USP UN 1072 OXYGEN 2 DO NOT REMOVE THIS PRODUCT LABEL. 13672 (04/06)
WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx only. Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless used in conjunction with resuscitative equipment. Produced by Air Liquefaction. DANGER: CONTAINS GAS UNDER PRESSURE. OXIDIZER. VIGOROUSLY ACCELERATES COMBUTSION.
Keep valves and fittings free from grease and other combustibles. Open valve slowly and close after each use. Keep away from heat., fumes or sparks. Transport, store, and use with adequate ventilation. Use only equipment cleaned for oxygen service and rated for cylinder pressure. Use a backflow prevention device in the piping. Cylinder temperature should not exceed 52°C (125° F). Always secure cylinder in an upright position. Read and follow the Safety Data Sheet (SDS) before use. CAS 7782-44-7
FOR CHEMICAL EMERGENCY INVOLVING THIS PRODUCT, CALL INFOTRAC 1-800-535-5053
-
Oxygen Body Label
RICHMOND OXYGEN
COMPANY
OXYGEN, COMPRESSED USP, UN1072 OXYGEN 2
DO NOT REMOVE THIS LABEL OXYGEN 2 PRODUCED BY AIR LIQUEFACTION
Medical Gas
WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications. Rx only. Uninterrupted use of high concentrations of oxygen over a long duration without monitoring its effect on oxygen content of arterial blood, may be harmful. Use only with pressure reducing equipment and apparatus designed for oxygen. Do not attempt to use on patient’s ho have stopped breathing, unless use in conjunction with resuscitative equipment.
DANGER: CONTAINS GAS UNDER PRESSURE. OXIDIZER. VIGOROUSLY ACCELERATES COMBUSTION.
Keep valves and fittings free from grease and other combustibles. Open valve slowly and close valve after each use. Keep away from heat, flames, or sparks. Transport, store, and use with adequate ventilation. Use only equipment cleaned for oxygen service and rated for cylinder pressure. Use a backflow preventive device in the piping. Cylinder temperature should not exceed 52° C (125° F). Read and follow the Safety Data Sheet (SDS) before use. CAS 7782-44-7
Contents:
Cylinder type Liters
AA M4 114L _____
A M6 165L _____
B ML6 170L _____
M7 210L _____
C M9 249L _____
D MD 416L _____
DD M22 650L _____
E ME 685L _____
__ ____ ____ _____
RICHMOND OXYGEN COMPANY
11009 Richardson Road, Ashland, VA 23005
Phone: 804-798-2525
-
Oxygen Refrigerated
OXYGEN, REFRIGERATED LIQUID, USP UN1073
OXYGEN 2
ALWAYS KEEP CONTAINER IN UPRIGHT POSITION.
WARNING USP
For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx only.
Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless used in conjunction of resuscitative equipment.
Produced by Air Liquefaction.
Keep out of reach of children; and Federal law requires that this container be refilled with oxygen USP only by establishments registered as a drug manufacturer in accordance with the Federal Food, Drug, and Cosmetic Act.
DANGER:
MAY CAUSE OR INTENSIFY FIRE; OXIDER, CONTAINS REFRIGERATED GAS; MAY CAUSE CRYOGENIC BURNS OR INJURY. COMBUSTIBELS IN CONTACT WITH LIQUID OXYGEN MAY EXPLODE ON IGNITION OR IMPACT.
Do not handle until all safety precautions have been read and understood. Keep and store away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use and store only outdoors or in a well-ventilated place. Wear cold insulating gloves, face shield, and eye protection. In case of fire: Stop leak if safe to do so. Use a backflow preventive device in the piping. Use only the equipment of compatible materials equipment cleaned for oxygen service. DO NOT change or force fit connections. Avoid spills. Do not walk on or roll equipment over spills. Close valve after each use and when empty. Always keep container in upright position.
READ AND FOLLOW THE SAFETY DATA SHEET (SDS) BEFORE USE. CAS: 7782-44-7
FIRST AID FIRST AID: IF ON SKIN: Thaw affected parts with lukewarm water. Do not rub affected area. Get immediate medical advice/attention.
Lot Number:
Contents:
Expiration Date:
Richmond Oxygen
11009 Richardson Road
Ashland, VA 23005
DO NOT REMOVE THIS PRODUCT LABEL
-
INGREDIENTS AND APPEARANCE
OXYGEN
oxygen gasProduct Information Product Type HUMAN PRESCRIPTION DRUG Item Code (Source) NDC:59534-001 Route of Administration RESPIRATORY (INHALATION) Active Ingredient/Active Moiety Ingredient Name Basis of Strength Strength Oxygen (UNII: S88TT14065) (Oxygen - UNII:S88TT14065) Oxygen 99 L in 100 L Packaging # Item Code Package Description Marketing Start Date Marketing End Date 1 NDC:59534-001-01 113 L in 1 CYLINDER; Type 0: Not a Combination Product 05/02/1992 2 NDC:59534-001-02 170 L in 1 CYLINDER; Type 0: Not a Combination Product 05/02/1992 3 NDC:59534-001-03 165 L in 1 CYLINDER; Type 0: Not a Combination Product 05/02/1992 4 NDC:59534-001-04 210 L in 1 CYLINDER; Type 0: Not a Combination Product 05/02/1992 5 NDC:59534-001-05 248 L in 1 CYLINDER; Type 0: Not a Combination Product 05/02/1992 6 NDC:59534-001-06 425 L in 1 CYLINDER; Type 0: Not a Combination Product 05/02/1992 7 NDC:59534-001-07 640 L in 1 CYLINDER; Type 0: Not a Combination Product 05/02/1992 8 NDC:59534-001-08 680 L in 1 CYLINDER; Type 0: Not a Combination Product 05/02/1992 9 NDC:59534-001-09 1724 L in 1 CYLINDER; Type 0: Not a Combination Product 05/02/1992 10 NDC:59534-001-10 3455 L in 1 CYLINDER; Type 0: Not a Combination Product 05/02/1992 11 NDC:59534-001-11 3512 L in 1 CYLINDER; Type 0: Not a Combination Product 05/02/1992 12 NDC:59534-001-12 6882 L in 1 CYLINDER; Type 0: Not a Combination Product 05/02/1992 13 NDC:59534-001-13 141991 L in 1 DEWAR; Type 0: Not a Combination Product 05/02/1992 Marketing Information Marketing Category Application Number or Monograph Citation Marketing Start Date Marketing End Date NDA NDA206023 05/02/1992 Labeler - Richmond Oxygen Company Inc. (112967955) Registrant - Richmond Oxygen Company Inc. (112967955) Establishment Name Address ID/FEI Business Operations Richmond Oxygen Company Inc. 112967955 manufacture(59534-001)