OXYGEN GAS OXYGEN GAS [ATLANTA MEDICAL GAS LLC]

OXYGEN GAS OXYGEN GAS [ATLANTA MEDICAL GAS LLC]
PDF | XML

NDC 42165-0001-0, 42165-0001-1, 42165-0001-2, 42165-0001-3, 42165-0001-4, 42165-0001-5, 42165-0001-6, 42165-0001-7, 42165-0001-8, 42165-0001-9, 42165-0002-1, 42165-0002-2, 42165-0002-3, 42165-0002-4
Set ID 79989e7b-e401-4927-bc5b-d9e78d248927
Category HUMAN PRESCRIPTION DRUG LABEL
Packager Atlanta Medical Gas LLC
Generic Name
Product Class
Product Number
Application Number
  • OXYGEN COMPRESSED LABEL

    MEDICAL GAS OXYGEN-2 OXYGEN COMPRESSED USP UN 1072 PRODUCED BY AIR LIQUEFACTION PROCESS

    DANGER: HIGH PRESSURE OXIDIZING GAS.  VIGOROUSLY ACCELERATES COMBUSTION.  STORE AND USE WITH ADEQUATE VENTILATION KEEP OIL AND GREASE AWAY.  OPEN VALVE SLOWLY.  USE ONLY WITH EQUIPMENT CLEANED FOR OXYGEN SERVICE AND RATED FOR CYLINDER PRESSURE.  CLOSE VALVE AFTER EACH USE AND WHEN EMPTY.  ALWAYS REPLACE CYLINDER CAP WHEN NOT IN USE.  REFER TO ATLANTA MEDICAL GAS MATERIAL SAFETY DATA SHEET. 

    HEALTH HAZARDS: INHALATION FOR PROLONGED EXPOSURE MAY RESULT IN PNEUMONIA.  ELEVATED CONCENTRATIONS PRESENT A RISK OF INFLAMMATION OR ORGANIC MATTER IN BODY.  FIRST AID: IF INHALED, REMOVE TO FRESH AIR.  IF NOT BREATHING GIVE ARTIFICIAL RESPIRATION, PREFERABLY MOUTH TO MOUTH.  CALL A PHYSICIAN IMMEDIATELY AND ADVISE HIM OF EXPOSURE TO OXYGEN. 

    FOR EMERGENCY USE ONLY WHEN ADMINISTERED BY PROPERLY TRAINED PERSONNEL FOR OXYGEN DEFICIENCY AND RESUSCITATION.  FOR ALL OTHER MEDICAL APPLICATIONS Rx ONLY.   CAS#7782-44-7  L/333

    CONTENTS

    CYLINDER TYPE      LITERS

    T                              8688

    H                              7981

    M                              3198

    E                                 680

    DD                              640

    D                                 413

    C                                 248

    BB                              170

    B                                 170

    AA                              113

    AAA                           34

    COMPRESSED GAS LABEL

  • OXYGEN REFRIGERATED LIQUID

    MEDICAL GAS OXYGEN-2  OXYGEN REFRIGERATED LIQUID USP  UN1073  PRODUCED BY AIR LIQUEFACTION PROCESS

    WARNING: FOR EMERGENCY USE ONLY WHEN ADMINISTERED BY PROPERLY TRAINED PERSONNEL FOR OXYGEN DEFICIENCY AND RESUSCITATION.  FOR ALL OTHER MEDICAL APPLICATIONS Rx ONLY.  UNINTERRUPTED USE OF HIGH CONCENTRATIONS OF OXYGEN OVER A LONG DURATION, WITHOUT MONITORING ITS EFFECT ON OXYGEN CONTENT OF ARTERIAL BLOOD MAY BE HARMFUL.  USE ONLY WITH PRESSURE REDUCING EQUIPMENT AND APPARATUS DESIGNED FOR OXYGEN.  DO NOT ATTEMPT TO USE ON PATIENTS WHO HAVE STOPPED BREATHING, UNLESS USED IN CONJUNCTION WITH RESUSCITATIVE EQUIPMENT.

    WARNING:  EXTREME COLD OXIDIZING LIQUID AND GAS UNDER PRESSURE. OXYGEN VIGOROUSLY ACCELERATES COMBUSTION.  COMBUSTIBLES IN CONTACT WITH LIQUID OXYGEN MAY EXPLODE ON IGNITION OR IMPACT.  CAN CAUSE SEVERE FROSTBITE.  OPEN VALVE SLOWLY AND CLOSE AFTER EACH USE.  KEEP AWAY FROM HEAT, FLAME, OR SPARKS.  KEEP OIL, GREASE, AND OTHER COMBUSTIBLES AWAY.  USE ONLY WITH EQUIPMENT CLEANED FOR OXYGEN SERVICE.  DO NOT STRIKE ARC OR LASER BEAM ON CYLINDER.  DO NOT GET LIQUID IN EYES, ON SKIN OR CLOTHING.  CONTAINER TEMPERATURE SHOULD NOT EXCEED 52 C (125 F) FOR LIQUID WITHDRAWAL, USE FACE SHIELD AND GLOVES.  USE SUITABLE HAND TRUCK FOR CONTAINER MOVEMENT.  DO NOT WALK ON OR ROLL EQUIPMENT OVER SPILLS.  TRANSPORT, STORE AND USE ADEQUATE VENTILATION.  ALWAYS SECURE CYLINDER IN UPRIGHT POSITION.  USE THIS PRODUCT IN ACCORDANCE WITH ITS SPECIFIC MATERIAL SAFETY DATA SHEET (MSDS), AVAILABLE AT ATLANTA MEDICAL GAS LLC.  DO NOT REMOVE THIS PRODUCT LABEL.  L/334  CAS# 7782-44-7

    CONTENTS

    CYLINDER TYPE   LITERS

    160L                     123048

    180L                     137056

    200L                     142858

    230L                     167819

    LIQUID LABEL

  • INGREDIENTS AND APPEARANCE
    OXYGEN 
    oxygen gas
    Product Information
    Product TypeHUMAN PRESCRIPTION DRUGItem Code (Source)NDC:42165-0001
    Route of AdministrationRESPIRATORY (INHALATION)
    Active Ingredient/Active Moiety
    Ingredient NameBasis of StrengthStrength
    OXYGEN (UNII: S88TT14065) (OXYGEN - UNII:S88TT14065) OXYGEN99 L  in 100 L
    Packaging
    #Item CodePackage DescriptionMarketing Start DateMarketing End Date
    1NDC:42165-0001-034 L in 1 CAN
    2NDC:42165-0001-1113 L in 1 CYLINDER
    3NDC:42165-0001-2179 L in 1 CYLINDER
    4NDC:42165-0001-3248 L in 1 CYLINDER
    5NDC:42165-0001-4413 L in 1 CYLINDER
    6NDC:42165-0001-5640 L in 1 CYLINDER
    7NDC:42165-0001-6680 L in 1 CYLINDER
    8NDC:42165-0001-73198 L in 1 CYLINDER
    9NDC:42165-0001-87981 L in 1 CYLINDER
    10NDC:42165-0001-98688 L in 1 CYLINDER
    Marketing Information
    Marketing CategoryApplication Number or Monograph CitationMarketing Start DateMarketing End Date
    unapproved medical gas01/01/2007
    OXYGEN 
    oxygen gas
    Product Information
    Product TypeHUMAN PRESCRIPTION DRUGItem Code (Source)NDC:42165-0002
    Route of AdministrationRESPIRATORY (INHALATION)
    Active Ingredient/Active Moiety
    Ingredient NameBasis of StrengthStrength
    OXYGEN (UNII: S88TT14065) (OXYGEN - UNII:S88TT14065) OXYGEN99 L  in 100 L
    Packaging
    #Item CodePackage DescriptionMarketing Start DateMarketing End Date
    1NDC:42165-0002-1123048 L in 1 DEWAR
    2NDC:42165-0002-2137056 L in 1 DEWAR
    3NDC:42165-0002-3142658 L in 1 DEWAR
    4NDC:42165-0002-4167819 L in 1 DEWAR
    Marketing Information
    Marketing CategoryApplication Number or Monograph CitationMarketing Start DateMarketing End Date
    unapproved medical gas01/01/2007
    Labeler - Atlanta Medical Gas LLC (002151259)
    Registrant - Atlanta Medical Gas LLC (002151259)
    Establishment
    NameAddressID/FEIBusiness Operations
    Atlanta Medical Gas LLC002151259manufacture