OXYGEN USP HP SL Label
OXYGEN COMPRESSED USP UN 1072 OXYGEN 2 18033 (R 04/05)
WARNING: For emergency use only when administered by properly trained personnel for Oxygen deficiency and resuscitation. For all other medical applications, RX only. Uninterrupted use of high concentrations of Oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Use only with pressure reducing equipment and apparatus designed for Oxygen. Do not attempt to use on patients who have stopped breathing, unless used in conjunction with resuscitative equipment. Produced by Air Liquefaction.
WARNING: HIGH PRESSURE OXIDIZING GAS. VIGOROUSLY ACCELERATES COMBUSTION. Keep oil and grease away. Open valve slowly. Store and use with adequate ventilation.Use only with equipment cleaned for Oxygen service and rated for cylinder pressure. Use a back flow preventive device in piping. Close valve after each use and when empty. Cylinder pressure should not exceed 52 degrees C (125 degrees C). Use in accordance with the Material Safety Data Sheet (MSDS).
CAS: 7782-44-7 DO NOT REMOVE THIS LABEL
MED TECH Since 1961
Medical-Technical Gases, Inc.
20 Hall Street, Medford, MA 02155
TEL. 800 FINE GAS Fax (781) 395-9098
www.medtechgases.com
-
OXYGEN COMPRESSED USP Label
OXYGEN, COMPRESSED USP UN 1072 OXYGEN 2
WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, RX only.
CAUTION: Federal law prohibits dispensing without prescription.
Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Use only with pressure reducing equipment and apparatus designed for oxygen. Do not attempt to use on patients who have stopped breathing, unless used in conjunction with resuscitative equipment. Produced by Air Liquefaction.
WARNING: HIGH PRESSURE OXIDIZING GAS. VIGOROUSLY ACCELERATES COMBUSTION. Keep oil and grease away. Open valve slowly. Store and use with adequate ventilation.Use only with equipment cleaned for pxygen service and rated for cylinder pressure. Use a back flow preventive device in piping. Close valve after each use and when empty. Cylinder pressure should not exceed 52 degrees C (125 degrees C). Use in accordance with the Material Safety Data Sheet (MSDS).
CAS: 7782-44-7 DO NOT REMOVE THIS LABEL
MED TECH Since 1961
Medical-Technical Gases, Inc.
20 Hall Street, Medford, MA 02155
TEL. 800 FINE GAS Fax (781) 395-9098
www.medtechgases.com40035 (R 01/05)
-
OXYGEN REFRIGERATED LIQUID USP Label
REFRIGERATED LIQUID
OXYGEN REFRIGERATE LIQUID USP UN1073 OXYGEN 2
ALWAYS KEEP CONTAINER IN UPRIGHT POSITION.
DO NOT CHANGE OR FORCE FIT CONNECTIONS.
WARNING:
For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications Rx only.
Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen content of arterial blood, may be harmful. Use only with pressure reducing equipment and apparatus designed for oxygen. Do not attempt to use on patients who have stopped breathing, unless used in conjunction with resuscitative equipment.
Produced by Air Liquefaction.
WARNING:
EXTREMELY COLD, OXIDIZING LIQUID AND GAS UNDER PRESSURE.
VIGOROUSLY ACCELERATES COMBUSTION.
COMBUSTIBLES IN CONTACT WITH LIQUID OXYGEN MAY EXPLODE OR IGNITION OR IMPACT.
CAN CAUSE SEVERE FROSTBITE.
Keep oil, grease, and combustibles away.
Use only with equipment cleaned for oxygen service.
Store and use with adequate ventilation.
Do not get liquid in eyes, on skin, or clothing.
For liquid withdraw, wear face shield and gloves.
Do not drop. Use suitable hand truck for container movement.
Avoid spills. Do not walk on or roll equipment over spills.
Cylinder temperature should not exceed 52° C (125° F).
Close valve after each use and when empty.
Use a back flow preventive device in the piping.
Use in accordance with the Material Safety Data Sheet (MSDS).
FIRST AID: IN CASE OF FROSTBITE, obtain medical treatment immediately.
CAS: 7782-44-7
DO NOT REMOVE THIS LABELMedical-Technical Gases, Inc.
8 Executive Park drive North Billerica, MA 01862
tel. 800 FINE-GAS Fax (781) 395-9098
MED TECH Since 1961 www.medtechgases.com R 07-12 41533 (R 10/04)
-
INGREDIENTS AND APPEARANCE
OXYGEN
oxygen gasProduct Information Product Type HUMAN PRESCRIPTION DRUG Item Code (Source) NDC:10736-001 Route of Administration RESPIRATORY (INHALATION) Active Ingredient/Active Moiety Ingredient Name Basis of Strength Strength OXYGEN (UNII: S88TT14065) (OXYGEN - UNII:S88TT14065) OXYGEN 99 L in 100 L Packaging # Item Code Package Description Marketing Start Date Marketing End Date 1 NDC:10736-001-01 9487 L in 1 CYLINDER 2 NDC:10736-001-02 6919 L in 1 CYLINDER 3 NDC:10736-001-03 3596.6 L in 1 CYLINDER 4 NDC:10736-001-04 2378.9 L in 1 CYLINDER 5 NDC:10736-001-05 764.6 L in 1 CYLINDER 6 NDC:10736-001-06 368.2 L in 1 CYLINDER 7 NDC:10736-001-07 160 L in 1 DEWAR 8 NDC:10736-001-08 240 L in 1 DEWAR Marketing Information Marketing Category Application Number or Monograph Citation Marketing Start Date Marketing End Date unapproved medical gas 05/29/2012 Labeler - Medical-Technical Gases, Inc. (019481373) Registrant - Medical-Technical Gases, Inc. (019481373) Establishment Name Address ID/FEI Business Operations Medical-Technical Gases, Inc. 019481373 manufacture(10736-001) Establishment Name Address ID/FEI Business Operations Linde LLC 839692303 manufacture(10736-001)