NDC | 14080-001-01, 14080-001-02, 14080-001-03, 14080-001-04, 14080-001-05, 14080-001-06, 14080-001-07, 14080-001-08 |
Set ID | 857dae8d-ffeb-19fd-e053-2a91aa0a8dcf |
Category | HUMAN PRESCRIPTION DRUG LABEL |
Packager | KTL&C LLC dba RX Positive Medical Supply |
Generic Name | |
Product Class | |
Product Number | |
Application Number |
-
Principal for Oxygen Product
OXYGEN,
REFRIGERATED
LIQUID USP
UN 1073
CONTENTS ________________LITERS
CAS NO: 7782-44-7
DANGER:
REFRIGERATED LIQUEFIED OXIDIZING GAS. ALWAYS
KEEP CONTAINER IN UPRIGHT POSITION. DO NOT
CHANGE OR FORCE FIT CONNECTIONS. MAY CAUSE OR INTENSIFY
FIRE; OXIDIZER, CONTAINS REFRIGERATED GAS: MAY CAUSE
CRYOGENIC BURNS OR INJURY. COMBUSTIBLES IN CONTACT WITH
LIQUID OXYGEN MAY EXPLODE ON IGNITION OR IMPACT.
Do not get in eyes, on skin, or on clothing. Keep reduction valves free
from grease and oil. In case of fire, stop leak if safe to do so. Avoid
spills. Do not walk or roll equipment over spills. Store and use in a well
ventilated place. Use only with equipment of compatible materials
of construction and rated for cylinder pressure. Wear cold insulating
gloves/face shield/eye protection. Protect from sunlight when ambient
temperature exceeds 52 F. Container temperature should
not exceed 52 F. Close valve after each use and when
empty. Use a back flow preventative device in the piping. Do not
handle until all safety precautions have been read and understood.
Use only with equipment cleaned for oxygen service. Keep/store away
from combustible materials. Do not drop. Use suitable hand truck for
container movement.
FIRST AID:
IN CASE OF FROSTBITE: Thaw frosted parts with lukewarm water.
Do not rub affected area. Get immediate medical advice/attention.
DO NOT REMOVE THIS PRODUCT LABEL.
For emergency use only when administered by properly trained
personnel for oxygen deficiency and resuscitation. For all other medical
applications, Rx only. Uninterrupted use of high concentrations of
oxygen over a long duration, without monitoring its effect on oxygen
content of arterial blood, may be harmful. Use only with pressure
reducing equipment and apparatus designed for oxygen. Do not
attempt to use on patients who have stopped breathing unless used in
conjunction with resuscitative equipment. Produced by Air Liquefaction.
ALWAYS KEEP CONTAINER IN UPRIGHT POSITION
OXYGEN
COMPRESSED
USP
UN 1072
DANGER:
MAY CAUSE OR INTENSIFY FIRE; OXIDIZER. CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED.
Do not handle until all safety precautions have been read and understood. Keep and store away from clothing and other combustible materials. Keep valves and fittings free from grease and oil. Use and store only outdoors or in a well-ventilated place. In case of fire: Stop leak if safe to do so. Use a back flow preventive device in the piping. Use only with equipment of compatible materials of construction and rated for cylinder pressure. Use only with equipment cleaned for oxygen service. Open valve slowly. Close valve after each use and when empty. Protect from sunlight when ambient temperature exceeds 52 °c (125 °F). Read and follow the Safety Data Sheet (SDS) before use.CAS NO: 7782-44-7
DO NOT REMOVE THIS PRODUCT LABEL.
WARNING: For emergency use only when administered by properly trained personnel for oxygen deficiency
and resuscitation. For all other medical applications, Rx only.
Uninterrupted use of high concentrations of oxygen over a long duration, without monitoring its effect on oxygen
content of arterial blood, may be harmful. Do not attempt to use on patients who have stopped breathing unless used in conjunction with resuscitative equipment. Produced by Air Liquefaction.
-
INGREDIENTS AND APPEARANCE
OXYGEN
oxygen gasProduct Information Product Type HUMAN PRESCRIPTION DRUG Item Code (Source) NDC:14080-001 Route of Administration RESPIRATORY (INHALATION) Active Ingredient/Active Moiety Ingredient Name Basis of Strength Strength OXYGEN (UNII: S88TT14065) (OXYGEN - UNII:S88TT14065) OXYGEN 99 L in 100 L Packaging # Item Code Package Description Marketing Start Date Marketing End Date 1 NDC:14080-001-01 164 L in 1 CYLINDER; Type 0: Not a Combination Product 10/01/2014 2 NDC:14080-001-02 255 L in 1 CYLINDER; Type 0: Not a Combination Product 10/01/2014 3 NDC:14080-001-03 425 L in 1 CYLINDER; Type 0: Not a Combination Product 10/01/2014 4 NDC:14080-001-04 640 L in 1 CYLINDER; Type 0: Not a Combination Product 10/01/2014 5 NDC:14080-001-05 680 L in 1 CYLINDER; Type 0: Not a Combination Product 10/01/2014 6 NDC:14080-001-06 3455 L in 1 CYLINDER; Type 0: Not a Combination Product 10/01/2014 7 NDC:14080-001-07 7080 L in 1 CYLINDER; Type 0: Not a Combination Product 10/01/2014 8 NDC:14080-001-08 100 L in 1 DEWAR; Type 0: Not a Combination Product 10/01/2014 Marketing Information Marketing Category Application Number or Monograph Citation Marketing Start Date Marketing End Date unapproved medical gas 10/01/2014 Labeler - KTL&C LLC dba RX Positive Medical Supply (183434807) Establishment Name Address ID/FEI Business Operations KTL&C LLC dba RX Positive Medical Supply 183434807 manufacture(14080-001)