NDC | 45567-0555-1, 45567-0555-2 |
Set ID | e545ac6a-83dc-485a-8bb4-c0b9d8f3d144 |
Category | HUMAN PRESCRIPTION DRUG LABEL |
Packager | Sun Pharmaceutical Industries, Inc. |
Generic Name | |
Product Class | |
Product Number | |
Application Number | ANDA079157 |
-
HIGHLIGHTS OF PRESCRIBING INFORMATION
These highlights do not include all the information needed to use Kit for the Preparation of Technetium Tc 99m Sestamibi for Injection safely and effectively. See full prescribing information for Kit for the Preparation of Technetium Tc 99m Sestamibi for Injection.
Kit for the Preparation of Technetium Tc 99m Sestamibi for Injection
Kit for intravenous use
Initial U.S. Approval: 1990INDICATIONS AND USAGE
Technetium Tc 99m Sestamibi, is a myocardial perfusion agent indicated for:
DOSAGE AND ADMINISTRATION
- •
- For Myocardial Imaging: The suggested dose range for I.V. administration of Technetium Tc 99m Sestamibi in a single dose to be employed in the average patient (70 Kg) is 370-1110 MBq (10-30 mCi) (2).
- •
- For Breast Imaging: The recommended dose range for I.V. administration of Technetium Tc 99m Sestamibi is a single dose of 740-1110 MBq (20-30 mCi) (2).
DOSAGE FORMS AND STRENGTHS
- •
- Kit for the Preparation of Technetium Tc 99m Sestamibi for Injection is supplied as a lyophilized mixture in 10 mL vials in a kit of five (5) (NDC # 45567-0555-1) or a kit of (30) (NDC # 45567-0555-2), sterile and non-pyrogenic (3).
CONTRAINDICATIONS
- •
- None known.
WARNINGS AND PRECAUTIONS
- •
- Pharmacologic induction of cardiovascular stress may be associated with serious adverse events such as myocardial infarction, arrhythmia, hypotension, bronchoconstriction and cerebrovascular events (5.1).
- •
- Technetium Tc 99m Sestamibi has been rarely associated with acute severe allergic and anaphylactic events of angioedema and generalized urticaria. In some patients the allergic symptoms developed on the second injection during Technetium Tc 99m Sestamibi imaging (5.1).
- •
- Caution should be exercised and emergency equipment should be available when administering Technetium Tc 99m Sestamibi (5.1).
- •
- Before administering Technetium Tc 99m Sestamibi patients should be asked about the possibility of allergic reactions to either drug (5.1).
- •
- The contents of the vial are intended only for use in the preparation of Technetium Tc 99m Sestamibi and are not to be administered directly to the patient without first undergoing the preparative procedure (5.2).
ADVERSE REACTIONS
The following adverse reactions have been reported in ≤ 0.5% of patients: signs and symptoms consistent with seizure occurring shortly after administration of the agent; transient arthritis; angioedema, arrhythmia, dizziness, syncope, abdominal pain, vomiting, and severe hypersensitivity characterized by dyspnea, hypotension, bradycardia, asthenia, and vomiting within two hours after a second injection of Technetium Tc 99m Sestamibi. A few cases of flushing, edema, injection site inflammation, dry mouth, fever, pruritis, rash, urticaria and fatigue have also been attributed to administration of the agent (6).
To report SUSPECTED ADVERSE REACTIONS, contact Sun Pharmaceutical Industries, Inc.at 1-800-221-7554 or 781-275-7120 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.(6)
DRUG INTERACTIONS
- •
- Specific drug-drug interactions have not been studied (7).
USE IN SPECIFIC POPULATIONS
- •
- In one study of 46 subjects who received Lantheus Medical Imaging's Technetium Tc99m Sestamibi administration, the radioactivity in both children and adolescents exhibited blood PK profiles similar to those previously reported in adults (8.4).
- •
- Lactation: Interruption of breastfeeding after exposure to Technetium Tc99m Sestamibi is not necessary, however, a lactating woman should be advised to consider restricting close contact with her breast fed infant to a maximum of 5 hours in the 24 hour period after Technetium Tc99m Sestamibi administration in order to minimize radiation exposure (8.2).
See 17 for PATIENT COUNSELING INFORMATION.
Revised: 3/2020
-
Table of Contents
FULL PRESCRIBING INFORMATION: CONTENTS*
1 INDICATIONS AND USAGE
2 DOSAGE AND ADMINISTRATION
2.1 Image Acquisition
2.2 Radiation Dosimetry
2.3 Instructions for Preparation
2.4 Determination of Radiochemical Purity in Technetium Tc 99m Sestamibi
3 DOSAGE FORMS AND STRENGTHS
4 CONTRAINDICATIONS
5 WARNINGS AND PRECAUTIONS
5.1 Warnings
5.2 General Precautions
6 ADVERSE REACTIONS
7 DRUG INTERACTIONS
8 USE IN SPECIFIC POPULATIONS
8.1 Pregnancy
8.2 Lactation
8.4 Pediatric Use
8.5 Geriatric Use
10 OVERDOSAGE
11 DESCRIPTION
11.1 Physical Characteristics
11.2 External Radiation
12 CLINICAL PHARMACOLOGY
12.1 Mechanism of Action
12.3 Pharmacokinetics
12.3.1 Metabolism
12.3.2 Elimination
13 NONCLINICAL TOXICOLOGY
13.1 Carcinogenesis, Mutagenesis, Impairment Of Fertility
14 CLINICAL STUDIES
16 HOW SUPPLIED/STORAGE AND HANDLING
17 PATIENT COUNSELING INFORMATION
- *
- Sections or subsections omitted from the full prescribing information are not listed.
-
1 INDICATIONS AND USAGE
Myocardial Imaging: Technetium Tc 99m Sestamibi Injection is a myocardial perfusion agent that is indicated for detecting coronary artery disease by localizing myocardial ischemia (reversible defects) and infarction (non-reversible defects), in evaluating myocardial function and developing information for use in patient management decisions. Technetium Tc 99m Sestamibi evaluation of myocardial ischemia can be accomplished with rest and cardiovascular stress techniques (e.g., exercise or pharmacologic stress in accordance with the pharmacologic stress agent’s labeling).
It is usually not possible to determine the age of a myocardial infarction or to differentiate a recent myocardial infarction from ischemia.
Breast Imaging: Technetium Tc 99m Sestamibi is indicated for planar imaging as a second line diagnostic drug after mammography to assist in the evaluation of breast lesions in patients with an abnormal mammogram or a palpable breast mass.
Technetium Tc 99m Sestamibi is not indicated for breast cancer screening, to confirm the presence or absence of malignancy, and it is not an alternative to biopsy.
-
2 DOSAGE AND ADMINISTRATION
For Myocardial Imaging: The suggested dose range for I.V. administration of Technetium Tc 99m Sestamibi in a single dose to be employed in the average patient (70 Kg) is 370–1110 MBq (10–30 mCi).
For Breast Imaging: The recommended dose range for I.V. administration of Technetium Tc 99m Sestamibi is a single dose of 740–1110 MBq (20–30 mCi).
2.1 Image Acquisition
Breast Imaging: It is recommended that images are obtained with a table overlay to separate breast tissue from the myocardium and liver, and to exclude potential activity that may be present in the opposite breast. For lateral images, position the patient prone with the isolateral arm comfortably above the head, shoulders flat against the table, head turned to the side and relaxed, with the breast imaged pendent through an overlay cutout. The breast should not be compressed on the overlay. For anterior images, position the patient supine with both arms behind the head. For either lateral or anterior images, shield the chest and abdominal organs, or remove them from the field of view.
For complete study, sets of images should be obtained five minutes after the injection, and in the following sequence:
Beginning five minutes after the injection of Technetium Tc 99m Sestamibi:
- •
- ten-minute lateral image of breast with abnormality
- •
- ten-minute lateral image of contralateral breast
- •
- ten-minute anterior image of both breasts
2.2 Radiation Dosimetry
The radiation doses to organs and tissues of an average patient (70 Kg) per 1110 MBq (30 mCi) of Technetium Tc 99m Sestamibi injected intravenously are shown in Table 1.
Table 1: Radiation Absorbed Doses from Tc 99m Sestamibi Estimated Radiation Absorbed Dose
REST
2.0 hour void
4.8 hour void
Organ
rads/30 mCi
mGy/1110 MBq
rads/30 mCi
mGy/1110 MBq
Breasts
0.2
2.0
0.2
1.9
Gallbladder Wall
2.0
20.0
2.0
20.0
Small Intestine
3.0
30.0
3.0
30.0
Upper Large Intestine Wall
5.4
55.5
5.4
55.5
Lower Large Intestine Wall
3.9
40.0
4.2
41.1
Stomach Wall
0.6
6.1
0.6
5.8
Heart Wall
0.5
5.1
0.5
4.9
Kidneys
2.0
20.0
2.0
20.0
Liver
0.6
5.8
0.6
5.7
Lungs
0.3
2.8
0.3
2.7
Bone Surfaces
0.7
6.8
0.7
6.4
Thyroid
0.7
7.0
0.7
7.0
Ovaries
1.5
15.5
1.6
15.5
Testes
0.3
3.4
0.4
3.9
Red Marrow
0.5
5.1
0.5
5.0
Urinary Bladder Wall
2.0
20.0
4.2
41.1
Total Body
0.5
4.8
0.5
4.8
STRESS
2.0 hour void
4.8 hour void
Organ
rads/30 mCi
mGy/1110 MBq
rads/30 mCi
mGy/1110 MBq
Breasts
0.2
2.0
0.2
1.8
Gallbladder Wall
2.8
28.9
2.8
27.8
Small Intestine
2.4
24.4
2.4
24.4
Upper Large Intestine Wall
4.5
44.4
4.5
44.4
Lower Large Intestine Wall
3.3
32.2
3.3
32.2
Stomach Wall
0.6
5.3
0.5
5.2
Heart Wall
0.5
5.6
0.5
5.3
Kidneys
1.7
16.7
1.7
16.7
Liver
0.4
4.2
0.4
4.1
Lungs
0.3
2.6
0.2
2.4
Bone Surfaces
0.6
6.2
0.6
6.0
Thyroid
0.3
2.7
0.2
2.4
Ovaries
1.2
12.2
1.3
13.3
Testes
0.3
3.1
0.3
3.4
Red Marrow
0.5
4.6
0.5
4.4
Urinary Bladder Wall
1.5
15.5
3.0
30.0
Total Body
0.4
4.2
0.4
4.2
Radiation dosimetry calculations performed by Radiation Internal Dose Information Center, Oak Ridge Institute for Science and Education, PO Box 117, Oak Ridge, TN 37831-0117, (865) 576-3448.
2.3 Instructions for Preparation
Preparation of the Technetium Tc 99m Sestamibi from the Kit for Preparation of Technetium Tc 99m Sestamibi for Injection is done by the following aseptic procedure:
Boiling Water Bath Procedure
- 1.
- Prior to adding the Sodium Pertechnetate Tc 99m Injection to the vial, inspect the vial carefully for the presence of damage, particularly cracks, and do not use the vial if found. Tear off a radiation symbol and attach it to the neck of the vial.
- 2.
- Waterproof gloves should be worn during the preparation procedure. Remove the plastic disc from the vial and swab the top of the vial closure with alcohol to sanitize the surface.
- 3.
- Place the vial in a suitable radiation shield with a fitted radiation cap.
- 4.
- With a sterile shielded syringe, aseptically obtain additive-free, sterile, non-pyrogenic Sodium Pertechnetate Tc 99m Injection [925-5550 MBq, (25–150 mCi)] in approximately 1 to 3 mL.
- 5.
- Aseptically add the Sodium Pertechnetate Tc 99m Injection to the vial in the lead shield. Without withdrawing the needle, remove an equal volume of headspace to maintain atmospheric pressure within the vial.
- 6.
- Shake vigorously, about 5 to 10 quick upward-downward motions.
- 7.
- Remove the vial from the lead shield and place upright in an appropriately shielded and contained boiling water bath, such that the vial is suspended above the bottom of the bath, and boil for 10 minutes. Timing for 10 minutes is begun as soon as the water begins to boil again. Do not allow the boiling water to come in contact with the aluminum crimp.
- 8.
- Remove the vial from the water bath, place in the lead shield and allow to cool for 15 minutes.
- 9.
- Using proper shielding, the vial contents should be visually inspected. Use only if the solution is clear and free of particulate matter and discoloration.
- 10.
- Assay the reaction vial using a suitable radioactivity calibration system. Record the Technetium Tc 99m concentration, total volume, assay time and date, expiration time and lot number on the vial shield label and affix the label to the shield.
- 11.
- Store the reaction vial containing the Technetium Tc 99m Sestamibi at 20-25°C (68-77°F)[See USP] until use; at such time the product should be aseptically withdrawn. Technetium Tc 99m Sestamibi should be used within 6 hours of preparation. The vial contains no preservative.
- Note: Adherence to the above product reconstitution instructions is recommended.
- The potential for cracking and significant contamination exists whenever vials containing radioactive material are heated.
- Product should be used within 6 hours after preparation.
- Final product with radiochemical purity of at least 90% was used in the clinical trials that established safety and effectiveness. The radiochemical purity was determined by the following method.
- Sun Pharmaceutical Industries, Inc.’s Kit for the Preparation of Technetium Tc 99m Sestamibi for Injection is not to be used with the Recon-o-Stat™ thermal cycler due to the smaller vial size requirements of this heating device.
2.4 Determination of Radiochemical Purity in Technetium Tc 99m Sestamibi
- •
- Obtain a Baker-Flex Aluminum Oxide coated, plastic TLC plate, #1 B-F, pre-cut to 2.5 cm x 7.5 cm.
- •
- Dry the plate or plates at 100°C for 1 hour and store in a desiccator. Remove pre-dried plate from the desiccator just prior to use.
- •
- Apply 1 drop of ethanol* using a 1 mL syringe with a 22–26 gauge needle, 1.5 cm from the bottom of the plate. THE SPOT SHOULD NOT BE ALLOWED TO DRY.
- •
- Add 2 drops of Technetium Tc 99m Sestamibi solution, side by side on top of the ethanol* spot. Return the plate to a desiccator and allow the sample spot to dry (typically 15 minutes).
- •
- The TLC tank is prepared by pouring ethanol* to a depth of 3–4 mm. Cover the tank and let it equilibrate for ~10 minutes.
- •
- Develop the plate in the covered TLC tank in ethanol* for a distance of 5 cm from the point of application.
- •
- Cut the TLC plate 4 cm from the bottom and measure the Tc 99m activity in each piece by appropriate radiation detector.
- •
- Calculate the % Tc 99m Sestamibi as:
*The ethanol used in this procedure should be 95% or greater. Absolute ethanol (99%) should remain at ≥ 95% ethanol content for one week after opening if stored tightly capped, in a cool dry place.
- 3 DOSAGE FORMS AND STRENGTHS
- 4 CONTRAINDICATIONS
-
5 WARNINGS AND PRECAUTIONS
5.1 Warnings
In studying patients in whom cardiac disease is known or suspected, care should be taken to assure continuous monitoring and treatment in accordance with safe, accepted clinical procedure. Infrequently, death has occurred 4 to 24 hours after Tc 99m Sestamibi use and is usually associated with exercise stress testing (see Section 5.2).
Pharmacologic induction of cardiovascular stress may be associated with serious adverse events such as myocardial infarction, arrhythmia, hypotension, bronchoconstriction and cerebrovascular events. Caution should be used when pharmacologic stress is selected as an alternative to exercise; it should be used when indicated and in accordance with the pharmacologic stress agent’s labeling.
Technetium Tc 99m Sestamibi has been rarely associated with acute severe allergic and anaphylactic events of angioedema and generalized urticaria. In some patients the allergic symptoms developed on the second injection during Tc 99m Sestamibi imaging. Patients who receive Technetium Tc 99m Sestamibi for either myocardial or breast imaging are receiving the same drug. Caution should be exercised and emergency equipment should be available when administering Technetium Tc 99m Sestamibi. Also, before administering Technetium Tc 99m Sestamibi Injection, patients should be asked about the possibility of allergic reactions to the drug.
5.2 General Precautions
The contents of the vial are intended only for use in the preparation of Technetium Tc 99m Sestamibi and are not to be administered directly to the patient without first undergoing the preparative procedure.
Radioactive drugs must be handled with care and appropriate safety measures should be used to minimize radiation exposure to clinical personnel. Also, care should be taken to minimize radiation exposure to the patients consistent with proper patient management.
Contents of the kit before preparation are not radioactive. However, after the Sodium Pertechnetate Tc 99m Injection is added, adequate shielding of the final preparation must be maintained. The components of the kit are sterile and non-pyrogenic. It is essential to follow directions carefully and to adhere to strict aseptic procedures during preparation.
Technetium Tc 99m labeling reactions depend on maintaining the stannous ion in the reduced state. Hence, Sodium Pertechnetate Tc 99m Injection containing oxidants should not be used.
Technetium Tc 99m Sestamibi should not be used more than six hours after preparation.
Radiopharmaceuticals should be used only by physicians who are qualified by training and experience in the safe use and handling of radionuclides and whose experience and training have been approved by the appropriate government agency authorized to license the use of radionuclides.
Stress testing should be performed only under the supervision of a qualified physician and in a laboratory equipped with appropriate resuscitation and support apparatus.
The most frequent exercise stress test endpoints sufficient to stop the test reported during controlled studies (two-thirds were cardiac patients) were:
- •
- Fatigue 35%
- •
- Dyspnea 17%
- •
- Chest Pain 16%
- •
- ST-depression 7%
- •
- Arrhythmia 1%
-
6 ADVERSE REACTIONS
Adverse events were evaluated in 3741 adults who were evaluated in clinical studies. Of these patients, 3068 (77% men, 22% women, and 0.7% of the patients’ genders were not recorded) were in cardiac clinical trials and 673 (100% women) in breast imaging trials. Cases of angina, chest pain, and death have occurred (see Section 5). Adverse events reported at a rate of 0.5% or greater after receiving Technetium Tc 99m Sestamibi administration are shown in the following table:
Table 2: Selected Adverse Events Reported in > 0.5% of Patients Who Received Technetium Tc 99m Sestamibi in Either Breast or Cardiac Clinical Studies* Body System
Breast Studies
Cardiac Studies
Women
n = 673
Women
n = 685
Men
n = 2361
Total
n = 3046
Body as a Whole
21 (3.1%)
6 (0.9%)
17 (0.7%)
23 (0.8%)
Headache
11 (1.6%)
2 (0.3%)
4 (0.2%)
6 (0.2%)
Cardiovascular
9 (1.3%)
24 (3.5%)
75 (3.2%)
99 (3.3%)
Chest Pain/Angina
0 (0%)
18 (2.6%)
46 (1.9%)
64 (2.1%)
ST Segment Changes
0 (0%)
11 (1.6%)
29 (1.2%)
40 (1.3%)
Digestive System
8 (1.2%)
4 (0.6%)
9 (0.4%)
13 (0.4%)
Nausea
4 (0.6%)
1 (0.1%)
2 (0.1%)
3 (0.1%)
Special Senses
132 (19.6%)
62 (9.1%)
160 (6.8%)
222 (7.3%)
Taste Perversion
129 (19.2%)
60 (8.8%)
157 (6.6%)
217 (7.1%)
Parosmia
8 (1.2%)
6 (0.9%)
10 (0.4%)
16 (0.5%)
* Excludes the 22 patients whose genders were not recorded.
In the clinical studies for breast imaging, breast pain was reported in 12 (1.7%) of the patients. In 11 of these patients the pain appears to be associated with biopsy/surgical procedures.
The following adverse reactions have been reported in ≤ 0.5% of patients: signs and symptoms consistent with seizure occurring shortly after administration of the agent; transient arthritis; angioedema, arrhythmia, dizziness, syncope, abdominal pain, vomiting, and severe hypersensitivity characterized by dyspnea, hypotension, bradycardia, asthenia, and vomiting within two hours after a second injection of Technetium Tc 99m Sestamibi. A few cases of flushing, edema, injection site inflammation, dry mouth, fever, pruritus, rash, urticaria and fatigue have also been attributed to administration of the agent.
- 7 DRUG INTERACTIONS
-
8 USE IN SPECIFIC POPULATIONS
8.1 Pregnancy
Risk Summary
Limited available data with Technetium Tc99m Sestamibi use in pregnant women have not identified a drug-associated risk of major birth defects, miscarriage, or adverse maternal or fetal outcomes. Animal reproduction and teratogenicity studies have not been conducted with Technetium Tc99m Sestamibi. However, all radiopharmaceuticals have the potential to cause fetal harm depending on the fetal stage of development and the magnitude of the radiation dose. If considering Technetium Tc99m Sestamibi administration to a pregnant woman, inform the patient about the potential for adverse pregnancy outcomes based on the radiation dose from Technetium Tc99m Sestamibi and the gestational timing of exposure.
All pregnancies have a background risk of birth defects, loss, or other adverse outcomes. In the U.S. general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies is 2-4% and 15-20%, respectively
8.2 Lactation
Risk Summary
Limited data in the scientific literature on the presence of Technetium Tc99m Sestamibi in human milk, demonstrate that between 0.01% and 0.03% of maternal injected activity of technetium Tc99m Sestamibi was excreted in human milk. Technetium Tc99m Sestamibi accumulates in the lactating breast [see Clinical Considerations]. There are limited data in the scientific literature on effects of Technetium Tc99m Sestamibi on the breastfed infant or on milk production. The developmental and health benefits of breastfeeding should be considered along with the mother's clinical need for Technetium Tc99m Sestamibi and any potential adverse effects on the breastfed infant from Technetium Tc99m Sestamibi or from the underlying maternal condition.
Clinical Considerations
Interruption of breastfeeding after exposure to Technetium Tc99m Sestamibi is not necessary because Technetium Tc99m Sestamibi excretion in breast milk is low. However, a lactating woman may restrict close contact with her breast fed infant to a maximum of 5 hours in the 24 hour period after Technetium Tc99m Sestamibi administration in order to minimize radiation exposure.
8.4 Pediatric Use
Safety and effectiveness in the pediatric population have not been established.
No evidence of diagnostic efficacy or clinical utility of Technetium Tc99m Sestamibi scan was found in clinical studies of children and adolescents with Kawasaki disease.
A prospective study of 445 pediatric patients with Kawasaki disease was designed to determine the predictive value of Technetium Tc99m Sestamibi rest and stress myocardial perfusion imaging to define a pediatric population with Kawasaki disease that was at risk of developing cardiac events. Cardiac events were defined as cardiac death, MI, hospitalization due to cardiac etiology, heart failure, CABG or coronary angioplasty. The standard of truth was defined as cardiac events occurring 6 months following the administration of Technetium Tc99m Sestamibi. Only three cardiac events were observed at six months in this study. In all three cases, the scan was negative. No clinically meaningful measurements of sensitivity, specificity or other diagnostic performance parameters could be demonstrated in this study.
A ten year retrospective case history study of pediatric Kawasaki disease patients who completed Technetium Tc99m Sestamibi myocardial perfusion imaging and who had coronary angiography within three months of the Technetium Tc99m Sestamibi scan was designed to measure sensitivity and specificity of Technetium Tc99m Sestamibi scan. Out of 72 patients who had both evaluable Technetium Tc99m Sestamibi scans and evaluable angiographic images, only one patient had both an abnormal angiogram and an abnormal Technetium Tc99m Sestamibi scan. No clinically meaningful measurements of sensitivity, specificity or other diagnostic performance parameters could be demonstrated in this study.
In a clinical pharmacology study, 46 pediatric patients with Kawasaki disease received Technetium Tc99m Sestamibi administration at the following doses: 0.1-0.2 mCi/kg for rest, 0.3 mCi/kg for stress in one day studies; 0.2 mCi/kg for rest and 0.2 mCi/kg for stress in two day studies.
The radioactivity both in younger children and in adolescents exhibited PK profiles similar to those previously reported in adults (See Section 12).
The radiation absorbed doses in adolescents, both at rest and stress, were similar to those observed in adults (see Section 2). When comparing weight-adjusted radioactivity (up to 0.3 mCi/kg) doses administered to adolescents and younger children to the recommended dose administered to adults (up to 30 mCi ), the radiation absorbed doses in both adolescents and younger children were similar to those in adults.
Adverse events were evaluated in 609 pediatric patients from the three clinical studies described above. The frequency and the type of the adverse events were similar to the ones observed in the studies of Technetium Tc 99m Sestamibi in adults. Two of the 609 had a serious adverse event: one patient received a Technetium Tc 99m Sestamibi overdose but remained asymptomatic, and one patient had an asthma exacerbation following administration.
8.5 Geriatric Use
Of 3068 patients in clinical studies of the Kit for the Preparation of Technetium Tc 99m Sestamibi for myocardial imaging for injection, 693 patients were 65 or older and 121 were 75 or older.
Of 673 patients in clinical studies of the Kit for the Preparation of Technetium Tc 99m Sestamibi for breast imaging for injection, 138 patients were 65 or older and 30 were 75 or older.
Based on the evaluation of the frequency of adverse events and review of vital signs data, no overall differences in safety were observed between these subjects and younger subjects. Although reported clinical experience has not identified differences in response between elderly and younger patients, greater sensitivity of some older individuals cannot be ruled out.
- 10 OVERDOSAGE
-
11 DESCRIPTION
Each 10mL vial contains a sterile, non-pyrogenic, lyophilized mixture of:
- •
- Tetrakis (2-methoxy isobutyl isonitrile) Copper (I) tetrafluoroborate - 1 mg
- •
- Sodium Citrate Dihydrate - 2.6 mg
- •
- L-Cysteine Hydrochloride Monohydrate - 1 mg
- •
- Mannitol - 20 mg
- •
- Stannous Chloride, Dihydrate, minimum (SnCl2•2H2O) - 0.025 mg
- •
- Stannous Chloride, Dihydrate (SnCl2•2H2O) - 0.075 mg
- •
- Tin Chloride (stannous and stannic) Dihydrate, maximum (as SnCl2•2H2O) - 0.086 mg
Prior to lyophilization the pH is 5.4 to 5.7, and sodium hydroxide and/or hydrochloric acid may have been added for pH adjustment. The contents of the vial are lyophilized and stored under nitrogen.
This drug is administered by intravenous injection for diagnostic use after reconstitution with sterile, non-pyrogenic, oxidant-free Sodium Pertechnetate Tc 99m Injection. The pH of the reconstituted product is 5.5 (5.0–6.0). No bacteriostatic preservative is present.
The precise structure of the technetium complex is Tc 99m[MIBI]6 + where MIBI is 2-methoxy isobutyl isonitrile.
Tetrakis (2-methoxy isobutyl isonitrile) Copper (I) tetrafluoroborate has the following structural formula:
The molecular formula is C24H44N4O4BF4Cu, and the molecular weight is 602.98.
11.1 Physical Characteristics
Technetium Tc 99m decays by isomeric transition with a physical half-life of 6.02 hours.1 Photons that are useful for detection and imaging studies are listed below in Table 3.
Table 3 :Principal Radiation Emission Date Radiation
Mean %/
Disintegration
Mean
Energy (KeV)
Gamma-2
89.07
140.5
1Kocher, David, C., Radioactive Decay Data Tables, DOE/TIC-11026, 108(1981).
11.2 External Radiation
The specific gamma ray constant for Tc 99m is 5.4 microcoulombs/Kg-MBq-hr (0.78 R/mCi-hr) at 1 cm. The first half value layer is 0.017 cm of Pb. A range of values for the relative attenuation of the radiation emitted by this radionuclide that results from interposition of various thicknesses of Pb is shown in Table 4.To facilitate control of the radiation exposure from Megabequerel (millicurie) amounts of this radionuclide, the use of a 0.25 cm thickness of Pb will attenuate the radiation emitted by a factor of 1,000.
Table 4: Radiation Attenuation by Lead Shielding Shield Thickness (Pb) cm
Coefficient of Attenuation
0.017
0.5
0.08
10–1
0.16
10–2
0.25
10–3
0.33
10–4
To correct for physical decay of this radionuclide, the fractions that remain at selected intervals after the time of calibration are shown in Table 5.
Table 5: Physical Decay Chart; Tc 99m Half-Life 6.02 Hours Hours
Fraction Remaining
Hours
Fraction Remaining
0*
1.000
7
0.447
1
0.891
8
0.398
2
0.794
9
0.355
3
0.708
10
0.316
4
0.631
11
0.282
5
0.562
12
0.251
6
0.501
* Calibration Time
-
12 CLINICAL PHARMACOLOGY
12.1 Mechanism of Action
Technetium Tc 99m Sestamibi is a cationic Tc 99m complex which has been found to accumulate in viable myocardial tissue in a manner analogous to that of thallous chloride TI-201. Scintigraphic images obtained in humans after the intravenous administration of the drug have been comparable to those obtained with thallous chloride TI-201 in normal and abnormal myocardial tissue.
Animal studies have shown that myocardial uptake is not blocked when the sodium pump mechanism is inhibited. Although studies of subcellular fractionation and electron micrographic analysis of heart cell aggregates suggest that Tc 99m Sestamibi cellular retention occurs specifically within the mitochondria as a result of electrostatic interactions, the clinical relevance of these findings has not been determined.
The mechanism of Tc 99m Sestamibi localization in various types of breast tissue (e.g., benign, inflammatory, malignant, fibrous) has not been established.
12.3 Pharmacokinetics
Pulmonary activity is negligible even immediately after injection. Blood clearance studies indicate that the fast clearing component clears with a t½ of 4.3 minutes at rest, and clears with a t½ of 1.6 minutes under exercise conditions. At five minutes post injection about 8% of the injected dose remains in circulation. There is less than 1% protein binding of Technetium Tc 99m Sestamibi in plasma. The myocardial biological half-life is approximately six hours after a rest or exercise injection. The biological half-life for the liver is approximately 30 minutes after a rest or exercise injection. The effective half-life of clearance (which includes both the biological half-life and radionuclide decay) for the heart is approximately 3 hours, and for the liver is approximately 30 minutes, after a rest or exercise injection. The ideal imaging time reflects the best compromise between heart count rate and surrounding organ uptake.
Myocardial uptake which is coronary flow dependent is 1.2% of the injected dose at rest and 1.5% of the injected dose at exercise. Table 6 illustrates the biological clearance as well as effective clearance (which includes biological clearance and radionuclide decay) of Tc 99m Sestamibi from the heart and liver.
[Organ concentrations expressed as percentage of injected dose; data based on an average of 5 subjects at rest and 5 subjects during exercise.]
Table 6: Biological and Effective Clearance REST
Heart
Liver
Time
Biological
Effective
Biological
Effective
5 min.
1.2
1.2
19.6
19.4
30 min.
1.1
1.0
12.2
11.5
1 hour
1.0
0.9
5.6
5.0
2 hours
1.0
0.8
2.2
1.7
4 hours
0.8
0.5
0.7
0.4
STRESS
Heart
Liver
Time
Biological
Effective
Biological
Effective
5 min.
1.5
1.5
5.9
5.8
30 min.
1.4
1.3
4.5
4.2
1 hour
1.4
1.2
2.4
2.1
2 hours
1.2
1.0
0.9
0.7
4 hours
1.0
0.6
0.3
0.2
A study in a dog myocardial ischemia model reported that Technetium Tc 99m Sestamibi undergoes myocardial distribution (redistribution), although more slowly and less completely than thallous chloride TI-201. A study in a dog myocardial infarction model reported that the drug showed no redistribution of any consequence. Definitive human studies to demonstrate possible redistribution have not been reported. In patients with documented myocardial infarction, imaging revealed the infarct up to four hours post dose.
12.3.2 Elimination
The major pathway for clearance of Tc 99m Sestamibi is the hepatobiliary system. Activity from the gall bladder appears in the intestines within one hour of injection. Twenty-seven percent of the injected dose is excreted in the urine, and approximately thirty-three percent of the injected dose is cleared through the feces in 48 hours.
-
13 NONCLINICAL TOXICOLOGY
13.1 Carcinogenesis, Mutagenesis, Impairment Of Fertility
In comparison with most other diagnostic Technetium labeled radiopharmaceuticals, the radiation dose to the ovaries (1.5 rads/30 mCi at rest, 1.2 rads/30 mCi at exercise) is high. Minimal exposure (ALARA) is necessary in women of childbearing capability (see Section 2).
The active intermediate, Cu(MIBI)4BF4, was evaluated for genotoxic potential in a battery of five tests. No genotoxic activity was observed in the Ames, CHO/HPRT and sister chromatid exchange tests (all in vitro). At cytotoxic concentrations (>20 µg/mL), an increase in cells with chromosome aberrations was observed in the in vitro human lymphocyte assay. Cu(MIBI)4BF4 did not show genotoxic effects in the in vivo mouse micronucleus test at a dose which caused systemic and bone marrow toxicity (9 mg/kg, > 600 X maximal human dose).
-
14 CLINICAL STUDIES
Clinical Trials:
Myocardial Imaging: In a trial of rest and stress Tc 99m Sestamibi imaging, the relationship of normal or abnormal perfusion scans and long term cardiac events was evaluated in 521 patients (511 men, 10 women) with stable chest pain. There were 73.9% Caucasians, 25.9% Blacks and 0.2% Asians. The mean age was 59.6 years (range: 29 to 84 years). All patients had a baseline rest and exercise Tc 99m Sestamibi scan and were followed for 13.2 ± 4.9 months (range: 1 to 24 months). Images were correlated with the occurrence of a cardiac event (cardiac death or non-fatal myocardial infarction). In this trial as summarized in Table 7, 24/521 (4.6%) had a cardiac event.
Table 7: Cardiac Events Baseline Scan(a)
Proportion of patients
with events by scan results(a)
Proportion of scan result in patients with events; N=24(a)
Proportion of event-free patients by scan result(a)
Normal
1/206 (0.5%)
1/24 (4.2%)
205/206 (99.5%)
Abnormal
23/315 (7.3%)(b)
23/24 (95.8%)(b)
292/315 (92.7%)(b)
(a) Note: Similar findings were found in two studies with patients who had pharmacologic stress Tc 99m Sestamibi imaging.
(b) p<0.01
Although patients with normal images had a lower cardiac event rate than those with abnormal images, in all patients with abnormal images it was not possible to predict which patient would be likely to have further cardiac events; i.e., such individuals were not distinguishable from other patients with abnormal images.
The findings were not evaluated for defect location, disease duration, specific vessel involvement or intervening management.
In earlier trials, using a template consisting of the anterior wall, inferior-posterior wall and isolated apex, localization in the anterior or inferior-posterior wall in patients with suspected angina or coronary artery disease was shown. Disease localization isolated to the apex has not been established. In adults, Tc 99m Sestamibi has not been studied or evaluated in cardiac disorders other than coronary artery disease.
Breast Imaging: Technetium Tc 99m Sestamibi was evaluated in two multicenter, clinical trials of a total of 673 woman patients. Overall the mean age was 52 (range 23 to 87 years). The racial and ethnic representation was 70% Caucasian, 15% African-American, 14% Hispanic and 1% Asian.
Both clinical studies evaluated women who were referred for further evaluation for either: 1) a mammographically detected (with varying degrees of malignant likelihood) but not palpable breast lesion (study A, n=387, mean age = 54 years), or 2) a palpable breast lesion (study B, n=286, mean age = 50 years). In both studies all patients were scheduled for biopsy.
Technetium Tc 99m Sestamibi (20–30 mCi) was injected intravenously in a vein that was contralateral to the breast lesion in question. Planar imaging was completed with a high resolution collimator with a 10% window centered at 140 KeV, and 128 x 128 matrix. An initial marker image, that was not used in the data analysis, was obtained using a cobalt Co57 point source as a marker of a palpable mass. Images were obtained 5 minutes after injection as follows: lateral image of the affected breast for 10 minutes, lateral image of the contralateral breast for 10 minutes, and an anterior image of both breasts for 10 minutes. For the lateral image the patients were positioned in a prone position. For the anterior image, the patients were supine. The Technetium Tc 99m Sestamibi scintigraphic images were read in a randomized method by two groups of three blinded readers. Technetium Tc 99m Sestamibi uptake was scored as: normal (no uptake), equivocal, low, moderate, or high uptake. The results of Technetium Tc 99m Sestamibi images and mammography were analyzed in comparison to histopathologic findings of malignant or non-malignant disease.
As shown in Table 8 for the 483 evaluable patients, the sensitivity and specificity of any degree of Technetium Tc 99m Sestamibi uptake appear to vary with the presence or absence of palpable mass.
Table 8: Overall Technetium Tc 99m Sestamibi Blinded Results of Target Lesions(a) Identified at Study Entry(b) STATISTIC
Study A
Non-Palpable Mass and an
Abnormal Mammogram
Study B
Palpable Mass
Number of Patients and Lesions
N=277 Patients with 300 Lesions
N=206 Patients with 240 Lesions
Sensitivity
52(42,62)(c)
76(67,83)
Specificity
94(89,96)
85(77,91)
PPV(d)
79(67,88)
83(74,89)
NPV(d)
80(74,85)
78(69,84)
Agreement
80(75,85)
80(75,85)
Prevalence
32(27,37)
49(43,56)
(a) Excludes all discordant lesions not identified at entry and excludes 25 equivocal interpretations from Study A and 32 equivocal interpretations from Study B (see table 9 and Table 10)
(b) some patients had more than one target lesion
(c) Median and approximated 95% Confidence Interval
(d) PPV = Positive Predict Value; NPV = Negative Predict Value
In separate retrospective subset analyses of 259 patients with dense (heterogeneously/extremely dense) and 275 patients with fatty (almost entirely fat/numerous vague densities) breast tissue, the Technetium Tc 99m Sestamibi results were similar. Overall, the studies were not designed to compare the performance of Technetium Tc 99m Sestamibi with the performance of mammography in patients with breast densities or other coexistent breast tissue disorders.
In general the histology seems to correlate with the degree of Technetium Tc 99m Sestamibi uptake. As shown in Tables 9 and 10, the majority of the normal Technetium Tc 99m Sestamibi images are associated with non-malignant tissue (78–81%) and the majority of low, moderate or high uptake Technetium Tc 99m Sestamibi images are associated with malignant disease (79–83%). In an individual patient, however, the intensity of Technetium Tc 99m Sestamibi uptake can not be used to confirm the presence or absence of malignancy. Equivocal results do not have a correlation with histology.
Table 9: Degree of Technetium Tc 99m Sestamibi Breast Imaging Uptake in Comparison to Histopathology Results in Patients with Mammographically Detected Non-Palpable Lesions* (Study A) Normal Uptake
N = 249 lesions
Equivocal Uptake
N = 25 lesions
Low, Moderate or
High Uptake
N = 66 lesions
Non-malignant**
201 (81%)
14 (56%)
14 (21%)
Malignant
48 (19%)
11 (44%)
52 (79%)
* Median finding for 3 blinded readers
** Includes benign tissue, fibroadenoma, benign intramammary nodes, radial scar
Table 10: Degree of Technetium Tc 99m Sestamibi Breast Imaging Uptake in Comparison to Histopathology Results in Patients with Palpable Lesions* (Study B) Normal Uptake
N = 129 lesions
Equivocal Uptake
N = 32 lesions
Low, Moderate or
High Uptake
N = 115 lesions
Non-malignant**
100 (78%)
19 (59%)
20 (17%)
Malignant
29 (22%)
13 (41%)
95 (83%)
* Median finding for 3 blinded readers
** Includes benign tissue, fibroadenoma, benign intramammary nodes, radial scar
An estimate of the likelihood of malignancy based on the Technetium Tc 99m Sestamibi uptake score in combination with the mammographic score has not been studied.
In these two studies approximately 150 additional, non-biopsied lesions were found to be positive after Technetium Tc 99m Sestamibi imaging. These lesions were identified in sites that did not physically correlate with identified entry criteria mammographic lesions and these lesions were not palpable. These lesions were not biopsied. Whether these lesions were benign or malignant is not known. Technetium Tc 99m Sestamibi uptake can occur in both benign and malignant disease. THE CLINICAL USEFULNESS OF A POSITIVE TECHNETIUM TC 99M SESTAMIBI IMAGE IN THE ABSENCE OF AN ABNORMAL MAMMOGRAM OR A PALPABLE LESION IS NOT KNOWN.
-
16 HOW SUPPLIED/STORAGE AND HANDLING
Kit for the Preparation of Technetium Tc 99m Sestamibi for Injection is supplied as a lyophilized mixture in10 mL vials in a kit of five (5) (NDC #45567-0555-1) or a kit of thirty (30) (NDC #45567-0555-2), sterile and non-pyrogenic.
The patient dose should be measured by a suitable radioactivity calibration system immediately prior to patient administration. Radiochemical purity should be checked prior to patient administration.
Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration whenever solution and container permit.
Prior to lyophilization the pH is between 5.4–5.7. The contents of the vial are lyophilized and stored under nitrogen. Store at 20-25°C (68-77°F)[See USP] before and after reconstitution. Kit for the Preparation of Technetium Tc 99m Sestamibi Injection contains no preservatives. Included in each five (5) vial kit is one (1) package insert, six (6) vial shield labels and six (6) radiation warning labels. Included in each thirty (30) vial kit is one (1) package insert, thirty-six (36) vial shield labels and thirty-six (36) radiation warning labels.
This reagent kit for preparation of a radiopharmaceutical is approved for use by persons licensed pursuant to Section 120.547 Code of Massachusetts Regulation 105, or under equivalent license of the U.S. Nuclear Regulatory Commission of an Agreement State.
-
17 PATIENT COUNSELING INFORMATION
CARDIOLITE® and MIRALUMA® are different names for the same drug (Kit for the Preparation of Technetium Tc 99m Sestamibi for Injection). Patients should be advised to inform their health care provider if they had an allergic reaction to either drug or if they had an imaging study with either drug.
CARDIOLITE, MIRALUMA and Recon-o-Stat are trademarks of Lantheus Medical Imaging, Inc.
Lactation: Interruption of breastfeeding after exposure to Technetium Tc99m Sestamibi is not necessary, however, a lactating woman should be advised to consider restricting close contact with her breast fed infant to a maximum of 5 hours in the 24 hour period after Technetium Tc99m Sestamibi administration in order to minimize radiation exposure [see Use in Specific Populations (8.2)].
Manufactured by:
Sun Pharmaceutical Industries, Inc.
Billerica, MA 01821
For Customer Service call: 1-800-221-7554
(For International dial: 1-781-275-7120)PL-000022
Rev 2.0
Mar 2020
-
PACKAGE/LABEL - PRINCIPAL DISPLAY PANEL - 10 ml VIAL LABEL
Kit for the Preparation of Technetium Tc99m Sestamibi Injection
1mg Cu(MIBI)4BF4 per Vial
For Intravenous Use after Reconstitution
Rx Only
Dosage: See Package Insert
Store at 20-25ºC (68-77ºF) [See USP] before and after reconstitution.
Use within 6 hours after reconstitution.PL-000023
Rev 0.2
Mar 2020
Manufactured by:
Sun Pharmaceutical Industries, Inc.
Billerica, MA 01821
- Lot Exp
-
PACKAGE/LABEL - PRINCIPAL DISPLAY PANEL - SHIELD LABEL
CAUTION: RADIOACTIVE MATERIAL
See Package Insert for full prescribing information
Rx Only
Store: 20-25ºC
Use within 6 hours of reconstitutionTechnetium Tc99m Sestamibi Injection
Contents
1mg Tetrakis (2-methoxy isobutyl isonitrile)
Copper (I) tetrafluoroborate [Cu(MIBI)4BF4]
2.6mg Sodium Citrate dihydrate
1mg L-Cysteine hydrochloride monohydrate
20mg Mannitol
0.025mg minimum stannous chloride dihydrate
0.075mg stannous chloride dihydrate
0.086mg maximum tin chloride (stannous and stannic) dihydrate
Sodium Pertechnetate Tc99m Injection____________________________________________________
MBq (mCi) Tc99m/mL____________________________________________________
Volume mL____________________________________________________
Date / Time prepared Expiration Time______________________
Lot No.PL-000024
Rev 0.2
Mar 2020
Manufactured by:
Sun Pharmaceutical Industries, Inc.
Billerica, MA 01821
-
PACKAGE/LABEL - PRINCIPAL DISPLAY PANEL - 5 VIAL CARTON
Kit for the
Preparation of Technetium Tc99m
Sestamibi InjectionKit for the
Preparation of Technetium Tc99m
Sestamibi Injection1mg Cu(MIBI)4BF4 per Vial
For Intravenous Use after
ReconstitutionRx Only
Nonradioactive • Diagnostic Agent • Multidose
Sterile • Non-Pyrogenic
Vial contents are sealed under Nitrogen
at time of manufacture. The pH of
the reconstituted product is 5.5Dosage: See Package Insert
Manufactured by:
Sun Pharmaceutical Industries, Inc.
Billerica, MA 01821
For Customer Service call: 1-800-221-7554Kit for the
Preparation of Technetium Tc99m
Sestamibi Injectionfor:
Myocardial or Breast Imaging
Rx Only
Each sterile, lyophilized vial contains: 1mg Tetrakis
(2-methoxy isobutyl isonitrile) Copper (I) tetrafluoroborate
[Cu(MIBI)4BF4]; 2.6mg Sodium Citrate dihydrate; 1mg
L-Cysteine Hydrochloride monohydrate; 20mg Mannitol;
0.025mg minimum stannous chloride dihydrate; 0.075mg stannous
chloride dihydrate; 0.086mg maximum tin chloride (stannous
and stannic) dihydrate. pH of reconstituted product is 5.5CONTAINS NO PRESERVATIVE
Reconstitute with oxidant-free Tc99mBefore reconstitution and after labeling
with oxidant-free Technetium Tc 99m,
store at 20-25°C (68-77°F) [See USP]After labeling store in a suitable lead shield
and use within 6 hours (see insert).Contents: 1 package insert, 12 radiation
labels and 5 reaction vials
Preparation: See Package Insert for complete
information, use and directions
Kit for the
Preparation of
Technetium Tc99m
Sestamibi
InjectionIMPORTANT:
Read Package Insert for full
information on preparation,
use and indications.WARNING:
Radiopharmaceuticals should
be used by persons who are
qualified by specific training
in the safe use and handling
of radionuclides and whose
experience and training have
been approved by the
appropriate governmental
agency.
PL-000025Rev 0.3
Mar 2020
-
PACKAGE/LABEL - PRINCIPAL DISPLAY PANEL - 30 VIAL CARTON
Kit for the
Preparation of Technetium Tc99m
Sestamibi Injection1mg Cu(MIBI)4BF4 per Vial
for
Myocardial or Breast Imaging
For Intravenous Use after Reconstitution
Rx Only
Nonradioactive • Diagnostic Agent • Multidose
Sterile • Non-PyrogenicVial contents are sealed under Nitrogen
at time of manufacture. The pH of
the reconstituted product is 5.5Dosage: See Package Insert
Manufactured by:
Sun Pharmaceutical Industries, Inc.
Billerica, MA 01821
For Customer Service call: 1-800-221-7554Kit for the
Preparation of Technetium Tc99m
Sestamibi InjectionContents: 1 Package Insert, 72 radiation labels and 30 reaction vials
Each sterile, lyophilized vial contains: 1mg Tetrakis (2-methoxy isobutyl isonitrile) Copper (I) tetrafluoroborate [Cu(MIBI)4BF4]; 2.6mg Sodium Citrate dihydrate; 1mg L-Cysteine Hydrochloride monohydrate; 20mg Mannitol; 0.025mg minimum stannous chloride dihydrate; 0.075mg stannous chloride dihydrate; 0.086mg maximum tin chloride (stannous and stannic) dihydrate. pH of reconstituted product is 5.5
CONTAINS NO PRESERVATIVE • Reconstitute with oxidant-free Tc99m
Before reconstitution and after labeling with oxidant-free Technetium Tc 99m,
store at 20-25°C (68-77°F) [See USP]After labeling store in a suitable lead shield and use within 6 hours (see insert).
Preparation: See Package Insert for complete information, use and directions
Kit for the
Preparation of Technetium Tc99m
Sestamibi Injection1mg Cu(MIBI)4BF4 per Vial
For Intravenous Use after Reconstitution
Rx Only
Kit for the
Preparation of Technetium Tc99m
Sestamibi InjectionIMPORTANT:
Read Package Insert for full information on preparation, use and indications.
WARNING:
Radiopharmaceuticals should be used by persons who are qualified by specific
training in the safe use and handling of radionuclides and whose experience and
training have been approved by the appropriate governmental agency.Manufactured by:
Sun Pharmaceutical Industries, Inc.
Billerica, MA 01821
For Customer Service call: 1-800-221-7554PL-000026
Rev 0.3
Mar 2020
-
INGREDIENTS AND APPEARANCE
KIT FOR THE PREPARATION OF TECHNETIUM TC99M SESTAMIBI
technetium tc-99m sestamibi injectionProduct Information Product Type HUMAN PRESCRIPTION DRUG Item Code (Source) NDC:45567-0555 Route of Administration INTRAVENOUS Active Ingredient/Active Moiety Ingredient Name Basis of Strength Strength TECHNETIUM TC-99M SESTAMIBI (UNII: 971Z4W1S09) (TECHNETIUM TC-99M SESTAMIBI - UNII:971Z4W1S09) TECHNETIUM TC-99M SESTAMIBI 1 mg in 10 mL Inactive Ingredients Ingredient Name Strength TRISODIUM CITRATE DIHYDRATE (UNII: B22547B95K) 2.6 mg in 10 mL CYSTEINE HYDROCHLORIDE (UNII: ZT934N0X4W) 1 mg in 10 mL MANNITOL (UNII: 3OWL53L36A) 20 mg in 10 mL STANNOUS CHLORIDE (UNII: 1BQV3749L5) 0.075 mg in 10 mL Packaging # Item Code Package Description Marketing Start Date Marketing End Date 1 NDC:45567-0555-1 5 in 1 CARTON 07/10/2009 1 10 mL in 1 VIAL; Type 0: Not a Combination Product 2 NDC:45567-0555-2 30 in 1 CARTON 07/10/2009 2 10 mL in 1 VIAL; Type 0: Not a Combination Product Marketing Information Marketing Category Application Number or Monograph Citation Marketing Start Date Marketing End Date ANDA ANDA079157 07/10/2009 Labeler - Sun Pharmaceutical Industries, Inc. (139261648) Registrant - Sun Pharmaceutical Industries, Inc. (139261648) Establishment Name Address ID/FEI Business Operations Sun Pharmaceutical Industries, Inc. 139261648 LABEL(45567-0555) , PACK(45567-0555) , ANALYSIS(45567-0555) , MANUFACTURE(45567-0555)