ACD BLOOD-PACK UNITS (PL 146 PLASTIC) (ANTICOAGULANT CITRATE DEXTROSE (ACD)) SOLUTION [FENWAL, INC.]

ACD BLOOD-PACK UNITS (PL 146 PLASTIC) (ANTICOAGULANT CITRATE DEXTROSE (ACD)) SOLUTION [FENWAL, INC.]
PDF | XML

NDC 0942-9001-01
Set ID ba894daa-688e-4a9e-bd74-e71797f951bb
Category Human Prescription Drug Label
Packager Fenwal, Inc.
Generic Name
Product Class Anti-coagulant
Product Number
Application Number BN160918
  • Instructions for Blood Collection Using CPD or ACD Single Blood-Pack™ Units

    Integral Donor Tube (IDT)

    Rx only

    Use aseptic technique.

    Precaution: Do not use unless solution is clear.

    1.
    Identify Blood-Pack unit using appropriate donor identification system. Confirm that all numbered tubing of each Blood-Pack unit contains its own identical segment numbers.
    2.
    Adjust donor scale to desired collection weight.
    3.
    Position primary container from donor scale as far as possible below donor arm and clamp donor tubing with hemostat.
    4.
    Apply pressure to donor’s arm and disinfect site of venipuncture.
    5.
    If blood pressure cuff is used, inflate to approximately 60 mmHg.
    6.
    Remove needle cover per instructions below:
    (a)
    Holding the hub and cover near the tamper-evident seal, twist cover 1/4 turn to break seal.
    (b)
    Remove needle cover, being careful not to drag the cover across the needle point.
     
    Perform venipuncture, appropriately secure donor needle and/or tubing and release hemostat.
    7.
    Mix blood and anticoagulant at several intervals during collection and immediately after collection.
    8.
    Collect the appropriate volume based on Blood-Pack unit used. Note: The volume of anticoagulant is sufficient for the blood collection indicated on Blood-Pack unit ± 10%.
    9.
    Apply hemostat to donor tube.
    10.
    As appropriate, release pressure on the donor’s arm, collect donor samples following established procedures and withdraw donor needle.Precaution: Use care to avoid accidental needle sticks. One of the Fenwal Needle Protector Systems may be used to reduce the risk of needle stick injury.Strip blood from donor tubing into container, mix and allow the tubing to refill; repeat once. Seal at X marks on donor tubing to provide numbered aliquots of anticoagulated blood for typing or crossmatching.
    11.
    Strip blood from donor tubing into container, mix and allow the tubing to refill; repeat once. Seal at X marks on donor tubing to provide numbered aliquots of anticoagulated blood for typing or crossmatching.
    12.
    Discard needle into an appropriate biohazardous waste container following established procedures.
    13.
    Store filled unit between 1 and 6° C.
    14.
    Infuse blood within 21 days of collection.

    Store at Controlled Room Temperature.
    USP Definition of “Controlled Room Temperature”
    United States Pharmacopeia, General Notices.
    United States Phramacopeial Convention, Inc.
    12601 Twinbrook Parkway, Rockville, MD

    Fenwal and Blood-Pack are trademarks of Fenwal,Inc.
    logoManufacturer
    © 2009 Fenwal, Inc. All rights reserved.

    logo Fenwal, Inc.
    Lake Zurich, IL 60047 USA
    1-800-933-6925
    Made in USA

    07-19-02-335 REV: A 02/2009

  • PRINCIPAL DISPLAY PANEL

    PRINCIPAL DISPLAY PANEL

    Fenwal™

    Anticoagulant Citrate Dextrose Solution, USP (ACD) Formula A BLOOD-PACK™ Unit

    Single For Collection of 450 mL Blood

    Integral Donor Tube, 16 ga. Ultra Thin Wall Needle

    Rx only

    Each unit consists of a PL 146 Plastic primary container with 67.5 mL of ACD solution containing 1.65 g Dextrose (monohydrate) USP, 1.48 g Sodium Citrate (dihydrate) USP and 493 mg Citric Acid (anhydrous) USP.

    Sterile, non-pyrogenic fluid path
    See instructions for use.

    Store at Controlled Room Temperature (refer to direction insert).

     
    Open pouch by tearing across at notch.
     
    Direct handling of product surfaces prior to extended storage in the foil pouch, may result in mold growth.
     
    Unused units in open foil pouch may be kept up to 60 days by folding and securing open end of foil pouch to prevent possible loss of moisture, provided:

    l) Units are not removed from foil pouch, or

    ll) Unused units removed from foil pouch are returned to the foil pouch within 12 hours. Units may be removed from the pouch and returned only once.

    FENWAL and BLOOD-PACK are trademarks of Fenwal, Inc.

    logo Fenwal, Inc.
    Lake Zurich, IL 60047 USA
    Made in USA

    07-28-05-456 REV: A

    Anticoagulant Citrate Dextrose Solution, USP (ACD) Formula A BLOOD-PACK Unit label
  • INGREDIENTS AND APPEARANCE
    ACD BLOOD-PACK UNITS (PL 146 PLASTIC) 
    anticoagulant citrate dextrose (acd) solution
    Product Information
    Product TypeHUMAN PRESCRIPTION DRUGItem Code (Source)NDC:0942-9001
    Route of AdministrationINTRAVENOUS
    Active Ingredient/Active Moiety
    Ingredient NameBasis of StrengthStrength
    DEXTROSE MONOHYDRATE (UNII: LX22YL083G) (ANHYDROUS DEXTROSE - UNII:5SL0G7R0OK) DEXTROSE MONOHYDRATE1.65 g  in 67.5 mL
    TRISODIUM CITRATE DIHYDRATE (UNII: B22547B95K) (ANHYDROUS CITRIC ACID - UNII:XF417D3PSL) ANHYDROUS CITRIC ACID1.48 g  in 67.5 mL
    ANHYDROUS CITRIC ACID (UNII: XF417D3PSL) (ANHYDROUS CITRIC ACID - UNII:XF417D3PSL) ANHYDROUS CITRIC ACID493 mg  in 67.5 mL
    Inactive Ingredients
    Ingredient NameStrength
    WATER (UNII: 059QF0KO0R)  
    Packaging
    #Item CodePackage DescriptionMarketing Start DateMarketing End Date
    1NDC:0942-9001-0167.5 mL in 1 BAG; Type 0: Not a Combination Product
    Marketing Information
    Marketing CategoryApplication Number or Monograph CitationMarketing Start DateMarketing End Date
    NDABN16091803/01/2007
    Labeler - Fenwal, Inc. (794519020)
    Establishment
    NameAddressID/FEIBusiness Operations
    Fenwal International, Inc.091164590MANUFACTURE(0942-9001)